- 9 -
The LM Programmer software then shows in its first page the type and version number of the
firmware of the device.
6.1 Changing the device name
If multiple TC-4’s are used in a Log-Chain, each MUST be given a unique name so that
LogWorks can identify each TC-4. Just enter a name in the edit box in this page.
6.2 Updating the firmware
Click on the ‘Update Firmware’ button. You will be presented with a file dialog box that allows you
to select a firmware file. Firmware files end with the file extension .dld.
TC-4 firmware file names start with: TC4. The first part is followed by a dash, then a V, then the
version number without dots.
Example: TC-4 firmware version 1.00 alpha release would have the file name TC4-V100A.dld
TC4 firmware version 1.00 would have the file name TC4-V100.dld
After you opened the firmware file, this new firmware will be downloaded in the TC-4 device.
6.3 Configuring the Inputs
Click on the appropriate Input tab in the top of the window to configure one of the TC-4 inputs..
You can select for each input whether it is to be used for CHT or EGT range.