- 15 -
When setting the LC-1 to the slower response speed settings the measured mixture data will be
averaged over the response time setting before being output.
You can also specify what output voltage is visible on the analog outputs during warm-up of the
sensor and during error conditions.
The ‘High Impedance’ setting allows to specify that the analog outputs do not drive the output
during warm-up or error condition. They will be free floating. This is important for more closely
simulating a narrow band sensor. Many EFI systems monitor the impedance of a narrow band
sensor during engine warm-up to determine sensor readiness. A narrow band sensor that’s too
cold will have a high impedance.