Innovate-motorsports LM-2 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Instrumentos de medida Innovate-motorsports LM-2. Innovate Motorsports LM-2 User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 50
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
LM-2
Digital Air/Fuel Ratio Meter
User Manual
Note: This manual assumes that firmware version 1.10 or later is installed on your LM-2
Warning!
The Oxygen Sensor used in this device gets very hot in operation.
Do not touch the hot sensor. Do not let a hot sensor touch a combustible
surface. Do not use the sensor with or near flammable liquids or gases. Failure
to heed these warnings may result in severe burns, explosions or fires.
When installed in the exhaust, the oxygen sensor MUST be connected and
operating with the LM-2 whenever the car is running. An un-powered oxygen
sensor will be quickly damaged when exposed to hot exhaust gases.
Vista de página 0
1 2 3 4 5 6 ... 49 50

Resumo do Conteúdo

Página 1 - Warning!

LM-2 Digital Air/Fuel Ratio Meter User Manual Note: This manual assumes that firmware version 1.10 or later is installed on your LM-2

Página 2

Document # 31-0008 LM2_Manual_1.3.doc 10 2 Air/Fuel Ratio Setup Innovate Motorsports’ ‘Direct Digital’ wideband measurement principal allows you t

Página 3

Document # 31-0008 LM2_Manual_1.3.doc 11 The LM-2 must be powered by the cigarette adapter (12 volts) in order to properly heat the Oxygen sensor an

Página 4

Document # 31-0008 LM2_Manual_1.3.doc 12 Do NOT install the Bung below the 3 o'clock or 9 o'clock position. Condensation can form in the

Página 5 - 1.2 Status Bar

Document # 31-0008 LM2_Manual_1.3.doc 13 2.3 Calibration Schedule Normally aspirated (daily driver) - Calibrate before installation of new sensor -

Página 6

Document # 31-0008 LM2_Manual_1.3.doc 14 3 Software (LogWorks 3 and LM Programmer) It is important to install the provided software on the comput

Página 7

Document # 31-0008 LM2_Manual_1.3.doc 15 6. Select “Install the Device Automatically” and click Next. 7. A progress screen will appear. During thi

Página 8 - 1.5 Playback

Document # 31-0008 LM2_Manual_1.3.doc 16 6. Select the firmware file with the dld extension. 7. The software will now prompt you to put the LM-

Página 9

Document # 31-0008 LM2_Manual_1.3.doc 17 4. A window will pop up which will allow you to select the desired log from the memory card. Click Open.

Página 10 - 2 Air/Fuel Ratio Setup

Document # 31-0008 LM2_Manual_1.3.doc 18 4 OBD-II The LM-2 allows you to read up to 16 channels of “OBD-II” (“On Board Diagnostic) information direc

Página 11 - 2.2 Sensor Placement

Document # 31-0008 LM2_Manual_1.3.doc 19 4.2 Selecting Channels on the LM-2 1. Press and hold the Mode button to go into the Configuration Menu S

Página 12

Document # 31-0008 LM2_Manual_1.3.doc 2 TABLE OF CONTENT 1 LM-2...

Página 13 - 2.3 Calibration Schedule

Document # 31-0008 LM2_Manual_1.3.doc 20 4.3 Selecting Channels with the LM Programmer software 1. Connect the LM-2 to your computer with the prov

Página 14

Document # 31-0008 LM2_Manual_1.3.doc 21 4.4 OBD-II Channel Speed The first is a log trace of one channel (RPM) from a 2001 Lexus: Notice that

Página 15 - 3.2 Updating Firmware

Document # 31-0008 LM2_Manual_1.3.doc 22 Even if we zoom in to a closer time scale, the data is quite smooth. Performance is controlled by two th

Página 16

Document # 31-0008 LM2_Manual_1.3.doc 23 Like the Saturn, it is connected using 500K bit CAN, but we can begin to see some ‘steppiness’ in the RPM

Página 17

Document # 31-0008 LM2_Manual_1.3.doc 24 Since it is often a battle getting an ECU to deliver data fast enough, it is reasonable to ask why one woul

Página 18 - 4 OBD-II

Document # 31-0008 LM2_Manual_1.3.doc 25 With our racetrack shaped diagram fresh in mind, let’s look at Low Priority inputs in practice. In this ex

Página 19

Document # 31-0008 LM2_Manual_1.3.doc 26 But not all channels change quickly and we are more concerned with some channels than others. For exampl

Página 20

Document # 31-0008 LM2_Manual_1.3.doc 27 Now, when we log the data, RPM, SPARKADV, and FUEL1_OL, look like our original four channel log: This e

Página 21 - 4.4 OBD-II Channel Speed

Document # 31-0008 LM2_Manual_1.3.doc 28 2. Select OBD-II and press the Enter button. 3. Select Clear DTC Codes and press the Enter button. 4.8 C

Página 22

Document # 31-0008 LM2_Manual_1.3.doc 29 4.9 OBD II Basics OBD stands for “On Board Diagnostics”. It represents a collection of industry and legi

Página 23

Document # 31-0008 LM2_Manual_1.3.doc 3 1 LM-2 The LM-2 is a single or dual channel wideband controller with a built-in OBD II scan tool, RPM inpu

Página 24

Document # 31-0008 LM2_Manual_1.3.doc 30 (ISO 15765 standard or extended) but that still leaves about 12 years of ‘compromise’ vehicles. Fortunatel

Página 25

Document # 31-0008 LM2_Manual_1.3.doc 31 5 Analog Cable The provided analog cable has 14 stripped ends. The wire assignments are as follows: Analog

Página 26

Document # 31-0008 LM2_Manual_1.3.doc 32 Cylinder number and RPM calibrate number 4 Cyl engine Number of Cylinders 4-Stroke pulses/Crank-Rotation C

Página 27

Document # 31-0008 LM2_Manual_1.3.doc 33 5.2 Analog Inputs The LM-2 has 4 analog inputs for external 0-5V sensors. Each input has a corresponding

Página 28

Document # 31-0008 LM2_Manual_1.3.doc 34 5.3 Analog Outputs 5.3.1 Programming the analog outputs 1. Connect the LM-2 to your computer with the

Página 29 - 4.9 OBD II Basics

Document # 31-0008 LM2_Manual_1.3.doc 35 Note for Dual A/F channel units: You can program each analog output to represent the data from sensor 1 or

Página 30

Document # 31-0008 LM2_Manual_1.3.doc 36 5.3.3 Wiring Analog Outputs The analog outputs on the LM-2 are differential. As with the analog inputs, t

Página 31 - 5 Analog Cable

Document # 31-0008 LM2_Manual_1.3.doc 37 6 Tips, Tricks, & Troubleshooting 6.1 Air/Fuel and Lambda The Stoichiometric AFR value is the AFR mu

Página 32

Document # 31-0008 LM2_Manual_1.3.doc 38 6.2 General measurement requirements The LM-2 measures the air-fuel-ratio by measuring the amount of oxyg

Página 33 - 5.2 Analog Inputs

Document # 31-0008 LM2_Manual_1.3.doc 39 6.6 Sensor Timing Errors These errors are typically encountered when the sensor does not have outside air

Página 34 - 5.3 Analog Outputs

Document # 31-0008 LM2_Manual_1.3.doc 4 Top Bottom SD Memory Card Slot USB Connector Sensor Input # 2 (Enabled with

Página 35 - Advanced output programming

Document # 31-0008 LM2_Manual_1.3.doc 40 To connect the LM-2 to the EFI-computer, first determine what kind of narrow band sensor is used, then foll

Página 36 - Wiring Analog Outputs

Document # 31-0008 LM2_Manual_1.3.doc 41 6.8 Attenuating a Tach Signal The problem of an erratic tach signal happens if there is a lot of ringing

Página 37 - 6.1 Air/Fuel and Lambda

Document # 31-0008 LM2_Manual_1.3.doc 42 Appendix A: Specifications Power Power requirements Single Channel 8-14 Volt / 2 A (max, 1 A nominal)

Página 38 - 6.5 Diesel Engines

Document # 31-0008 LM2_Manual_1.3.doc 43 Appendix B: Limited Warranty LIMITED WARRANTY Innovate stands behind the quality of its products. Innovate

Página 39 - 6.6 Sensor Timing Errors

Document # 31-0008 LM2_Manual_1.3.doc 44 Appendix C: Connectors 1. Sensor 1 (2 optional) Pin Use 1 IPUMP+ 2 SENSE/PUMP- 3 SHTR 4 VBAT 5

Página 40

Document # 31-0008 LM2_Manual_1.3.doc 45 11 Analog In 4 + Peach 12 Analog Out 1 + Lime Green 13 Analog Out 2 + Brown/White 14 RPM + Black/Whit

Página 41

Document # 31-0008 LM2_Manual_1.3.doc 46 Appendix D: Supported PIDs Name – Description Units Min. Max "RPM - Engine RPM", &quo

Página 42 - Appendix A: Specifications

Document # 31-0008 LM2_Manual_1.3.doc 47 "SHRTFT32 - O2 Fuel Trim 3-2", "%", -100.0, 99.22, "O2S41 - O2 Sensor(NB) 4-

Página 43 - Appendix B: Limited Warranty

Document # 31-0008 LM2_Manual_1.3.doc 48 Appendix E: Error Codes and Troubleshooting Tips Error Code Error Message Likely Root Cause Fix Error 1

Página 44 - Appendix C: Connectors

Document # 31-0008 LM2_Manual_1.3.doc 49 Appendix F: Kit Contents 1. USB Cable (P/N 3813) 2. LM-2 3. Bung and Plug** (P/N 3735) 4. O2 Sensor**

Página 45

Document # 31-0008 LM2_Manual_1.3.doc 5 1.1 Main Screen There are 5 different screen view options. These can be cycled by pressing the Mode button.

Página 46 - Appendix D: Supported PIDs

Document # 31-0008 LM2_Manual_1.3.doc 50 12. Revision History 1.0 6/23/2008 Initial Release 1.1 7/10/08 Added RPM setup and LM Programmer configur

Página 47

Document # 31-0008 LM2_Manual_1.3.doc 6 During Recording, an upper case ‘R’ and a counter will display on the lower left: Counting minutes and seco

Página 48

Document # 31-0008 LM2_Manual_1.3.doc 7 connector. Last, “H” indicates that the unit is the MTS head unit. If the unit is not head this indicator

Página 49 - Appendix F: Kit Contents

Document # 31-0008 LM2_Manual_1.3.doc 8 1.4 Recording To start a record session press the Record button. The LM-2’s display will then inverse and th

Página 50 - 12. Revision History

Document # 31-0008 LM2_Manual_1.3.doc 9 Note: While the session is being played back you can pres the Menu button to cycle through the different dis

Comentários a estes Manuais

Sem comentários